Precision wrong autocalibration parameters

This commit is contained in:
Matteo Cypriani 2012-09-14 12:58:45 +02:00
parent 32926dd6c3
commit 94b4953aa8
12 changed files with 36 additions and 2 deletions

View File

@ -2,6 +2,9 @@ Humidity: 61%
Temperature: 23°C Temperature: 23°C
Hour: 14:40 Hour: 14:40
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.
Command-line parameters used to set owlps-client's options for each Command-line parameters used to set owlps-client's options for each
test: test:
- 10 ms: -F 10 -t 10 -n 100 -N 60 - 10 ms: -F 10 -t 10 -n 100 -N 60

View File

@ -2,11 +2,12 @@ Temperature: 22.5°C
Humidity: 56% Humidity: 56%
Hour: 14:45 (unfolded), 14:51 (folded) Hour: 14:45 (unfolded), 14:51 (folded)
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.
This test evaluates the impact of the mobile wall on measurements when This test evaluates the impact of the mobile wall on measurements when
it is unfolded. The CP used are the one at the East: TBF06 at the North it is unfolded. The CP used are the one at the East: TBF06 at the North
(1;10.60;1) and TBF07 at the South (1;0;1). (1;10.60;1) and TBF07 at the South (1;0;1).
The autocalibration was used, and each file contains 28 request from The autocalibration was used, and each file contains 28 request from
both CPs. both CPs.
The number of packets of the autocalibration requests is 15 instead of
20.

View File

@ -2,6 +2,9 @@ Temperature: 26°C
Humidity: 52% Humidity: 52%
Hour: 14:00 Hour: 14:00
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.
Each calibration point is measured in four directions (North, East, Each calibration point is measured in four directions (North, East,
South, West). South, West).
The office doors were closed during the calibration process. The office doors were closed during the calibration process.

View File

@ -1,3 +1,6 @@
Temperature: 25.5°C Temperature: 25.5°C
Humidity: 55% Humidity: 55%
Hour: 16:25 (1), 16:35 (2), 16:48 (5), 16:58 (7), 17:05 (10), 17:11 (11) Hour: 16:25 (1), 16:35 (2), 16:48 (5), 16:58 (7), 17:05 (10), 17:11 (11)
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.

View File

@ -2,6 +2,9 @@ Temperature: 24°C
Humidity: 58% Humidity: 58%
Hour: 10:45 Hour: 10:45
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.
This test was done with the following client parameters: This test was done with the following client parameters:
- 15 packets (-n15), - 15 packets (-n15),
- 10 ms between two packets (-t10), - 10 ms between two packets (-t10),

View File

@ -1,3 +1,6 @@
Temperature: 25.5°C Temperature: 25.5°C
Humidity: 57% Humidity: 57%
Hour: 15:15 Hour: 15:15
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.

View File

@ -1,3 +1,6 @@
Temperature: 24°C Temperature: 24°C
Humidity: 59% Humidity: 59%
Hour: 10:05 Hour: 10:05
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.

View File

@ -2,6 +2,9 @@ Temperature: 26°C
Humidity: 51% Humidity: 51%
Hour: 21:55 Hour: 21:55
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.
This test was done with the following client parameters: This test was done with the following client parameters:
- 15 packets (-n15), - 15 packets (-n15),
- 10 ms between two packets (-t10), - 10 ms between two packets (-t10),

View File

@ -2,6 +2,9 @@ Temperature: 25°C
Humidity: 55% Humidity: 55%
Hour: 12:05 Hour: 12:05
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.
This test was done with the following client parameters: This test was done with the following client parameters:
- 15 packets (-n15), - 15 packets (-n15),
- 10 ms between two packets (-t10), - 10 ms between two packets (-t10),

View File

@ -2,5 +2,8 @@ Temperature: 25.5°C
Humidity: 57% Humidity: 57%
Hour: 17:57 Hour: 17:57
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.
During this test all the offices were empty, except for office 1050. During this test all the offices were empty, except for office 1050.
People could also walk in the corridor. People could also walk in the corridor.

View File

@ -2,5 +2,8 @@ Temperature: 25.5°C
Humidity: 57% Humidity: 57%
Hour: 18:04 Hour: 18:04
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.
During this test all the offices were empty, except for office 1050. During this test all the offices were empty, except for office 1050.
People could also walk in the corridor. People could also walk in the corridor.

View File

@ -2,5 +2,8 @@ Temperature: 25.5°C
Humidity: 57% Humidity: 57%
Hour: 18:10 Hour: 18:10
/!\ The autocalibration was run with only 15 packets (-n15) instead of
20 and only 20 ms between two packets (-t20) instead of 25 ms.
Beside the operator, only one person was at the same floor, in the Beside the operator, only one person was at the same floor, in the
office 0180. office 0180.