owlps-experiments/v1.3.1/s17/s17_j20_fon_2012-06-18.txt

27 lines
1.7 KiB
Plaintext

Jeu de Test 20
Conditions :
Humidité : 68
Temperature: 20.7°
Heure du test : 11h45
taille des paquets : 116
Test effectué : Scénario 16
Listener command line: owlps-listenerd.semistatic -A -vvvv -i 192.168.11.254 -I 192.168.11.254 -n 10 -t 8 -r ath1 -w ath0
Mode opératoire :
- Start the aggregation server and one human operator waiting for 10 seconds in the 1st measurement point while the other operator waiting for 10 seconds in the 4th measurement point.
- After 10 seconds of waiting, the operators goes to the next measurement points: first operator goes to the 2nd measurement point while the other operator goes to the 3rd measurement point. In order to reach these measurement points, the operators walk one step per second, walking towards the measurement point. Once the measurement point is reached (it takes 4 seconds to reach the measuring point by walking meter by meter) turning in the direction of the measuring point number 1 (the time to turn is 1s what makes us a total of 5s ) and each operator stay 10s on it's measurement point.
- After waiting 10 seconds being oriented in the direction of the third point of measurement, first operator goes to the 3rd measurement point while the other operator goes to the 2nd measurement point. Time needed to complete this route is 10 seconds.
- Wait 10 seconds on the measurement point and then begin the migration to the measuring points number 4 (first operator) and 1 (second operator). The time needed to reach these points is 5 seconds
- After waiting 10 seconds, both operators walk to the 5th measurement point and stay there 10 seconds
Order of walking for the first operator: 1, 2, 3, 4, 5
Order of walking for the second operator: 4, 3, 2, 1, 5