Precision s15

This commit is contained in:
Matteo Cypriani 2012-07-13 10:31:09 +02:00 committed by Matteo Cypriani
parent dca8c83afc
commit 204252cefb
1 changed files with 15 additions and 0 deletions

View File

@ -26,3 +26,18 @@ Command for listener: owlps-listenerd.semistatic -A -vvvv -i 192.168.11.254 -I 1
le test se déroule de cette façon :
Durée du test 5 Min avec un temps d'attente de 1 minute à chaque point de mesures. Le fichier de sortie s'appel 2012-06-15_j17_s15.agg
> s15 (autocalibration with a human operator in the room but without mobile
> terminal): how can I know where is the operator at a given moment?
Very good question! I tried to find a logic and an order in that file but
I can't. I will explain you the way in which the experiment was made: I
sit 1 minute in #1 point. After, I walked about 6 seconds to reach the #2
point where I sit 1 minute. After, I walked 12 seconds to reach the #3
point where I sit 1 minute. 6 seconds to #4 point and 1 minute there. 6
seconds to #5 point and 1 minute there.
I had the same question as you, for the begining, about all these
experiments with autocalibration. It's impossible to know exactly where
the operator is.